10.5. AEDEX/EMAX Mode Command List
Command Code (hex) Function Description
! # 4 [DATA]
CR
21 23 34 [DATA] 0D Upper line message scroll
¾ Maximal [DATA] length is 40
! # 5 h h : m m
CR
21 23 35 h h ':' m m 0D Display time
¾ h, m = '0' ~ '9'
! # 8 n m CR 21 23 38 n m 0D Change attention code
¾ n, m = 1 ~ 20
! # 9 [DATA]
CR
21 23 39 [DATA] 0D Two line display
¾ Maximal [DATA] length is 40
! # 6 [DATA]
CR
21 23 36 [DATA] 0D Upper line message scroll once pass
¾ Maximal [DATA] length is 40
10.6. ADM787/788 mode command list
Command Code (hex) Function Description
CLR 0C Clear display
CR 0D Carriage return
SLE1 0E Clear upper line and move cursor to upper
left-end position
SLE2 0F Clear bottom line and move, Cursor to
bottom left-end position
DC0 n 10 n Set period to upper line last n position
¾ n = 31H ~ 37H
DC1 n 11 n Set line blinking, upper line
¾ n = '1' ~ '2'
n = '1': up line
n = '2': low line
DC2 n 12 n Clear line blinking, upper line
¾ n = '1' ~ '2'
n = '1': up line
n = '2': low line
SF1 1E Clear field 1 and move cursor to field 1, first
position
SF2 1F Clear field 2 and move cursor to field 2, first
position