Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Troubleshooting
T
roubleshooting Using the Messages 99
FATAL ERRORS
Fatal error messages appear on the LCD panel to warn users that an unrecoverable error has
occurred. However, in some cases the printer may recover if turned off and back on.
Table 3-29. Fatal Error
Item Description
LCD message SERVICE REQ. nnnnnnnn
LED indicator
status
All LED indicators flash.
Details
A fatal error occurs for one of the following reasons.
1) A problem occurred that the user cannot solve by himself.
2) A maintenance part has exceeded its useful life and if not replaced may
cause damage to the printer or printer parts.
3) An illegal function was attempted or illegal command received and the
operation is impossible.
Recovery
Turn off the printer and turn it back on. If the error does not recur, continue
normal operation.
If the same fatal error occurs when you turn the printer back on, see the
following table and perform the necessary service.
Type of Fatal
error
Refer to the next table.
Table 3-30. Fatal Error Code List
Code Description Refer to
00000100 Waste ink pads are full 3.3
00000101 CR motor life (Ink tubes also reached their life)
00000102 Nozzle check error compulsory continuity
00000103 RTC backup battery end
00000104 Auto print head optimization system
00000105 Head unit life end
00000106 Cleaning unit life end
00010000 PF motor/ encoder check error
00010001 PF motor out of step
00010002 PF motor/overcurrent
00010003 PF motor/ in position time-out error
00010004 CR motor/ encoder check error
00010005 CR motor/out of step
00010006 CR motor/overcurrent
00010007 CR motor/ in position time-out error
00010008 Servo interruption watch dog time out error
00010009 System interruption watch dog time out error
0001000A CR origin sensor mulfanction
0001000B PF origin sensor mulfanction
0001000C HS origin sensor mulfanction
0001000D Cover sensor mulfanction
0001000E Cover sensor mulfanction
0001000F CR motor over heat (PWM output malfunction)
00010010 PF motor over heat (PWM output malfunction)
00010011 Paper jam error
00010012 Cap origin error
00010013 Providing system origin error
00010014 Pressurization error
00010015 Liquid sensor overflow (K)
00010016 Liquid sensor overflow(C)
00010017 Liquid sensor overflow (M)
00010018 Liquid sensor overflow (LC)
Table 3-30. Fatal Error Code List (continued)
Code Description Refer to