Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Operating Principles Printer Mechanism Components 66
Mist adsorption fan Flushing unit +24V Brush-less fan
Ink that delivered it with the dot missing
detector is absorbed.
It discharges the air from the flushing duct
and pull the ink on the side of the flushing unit
and discharge it to the waste ink tank.
2.2.4
Front cover detection switch
L/R
Left/right guide frame +28V Microswitch
Interlocking to the protrusion that is in left
and right of the front cover the open and
close condition is detected
The secure device that the front cover inhibits
the printing actuation and laser output in the
condition that opened.
2.2.7
Cooling fan
Main frame back
inside
+5V Cooling the circuit boards. -
Name Mounting location
Drive
voltage
Type Explanation Function / control / others
Reference
clause