Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Product Description Maintenance Mode 52
.
*1 When hexadecimal dump mode is executed, "HEX MODE" is displayed.
Table1-36. MaintenanceModeSetupItems
Item Panel display Setup value
Print hexadecimal dump HEX DUMP
PRINT *1
Panel display language select LANGUAGE
ENGLISH, FRENCH,
ITALIAN, GERMAN,
SPANISH, PORTUGUE
Parallel interface mode PARA. I/F
ECP
,COMPAT
Set IEEE1284.4 IEEE1284.4
ON,OFF
Auto nozzle check AUTO NOZZLE CHK.
ON
,OFF
Ink information (K) K CARTRIDGE INFO
(Ink information menu)
Ink information (C) C
CARTRIDGE INFO
(Ink information menu)
Ink information (M) M CARTRIDGE INFO
(Ink information menu)
Ink information (Lc) Lc
CARTRIDGE INFO
(Ink information menu)
Inkinformation(Lm) Lm CARTRIDGE INFO
(Ink information menu)
Ink information (Y) Y
CARTRIDGE INFO
(Ink information menu)
Gap adjustment menu HEAD ALIGNMENT MENU
Paper feed adjustment mode
table1
(Pigment, PH=less than
0.1mm)
XX1=<nn>:<mm>
<nn>:00H-C9H
<mm>:00H-09H,FFH
Paper feed adjustment mode
table2
(Pigment, PH=less than
0.2mm)
XX2=<nn>:<mm>
<nn>:00H-C9H
<mm>:00H-09H,FFH
Paper feed adjustment mode
table3
(Dye, PH=less than 0.1mm)
XX3=<nn>:<mm>
<nn>:00H-C9H
<mm>:00H-09H,FFH
Paper feed adjustment mode
table4
(Dye, PH=less than 0.2mm)
XX4=<nn>:<mm>
<nn>:00H-C9H
<mm>:00H-09H,FFH
Paper feed adjustment mode
table5
(Dye/Pigment, PH=less than
0.5mm)
XX5=<nn>:<mm>
<nn>:00H-C9H
<mm>:00H-09H,FFH
Paper feed adjustment offset
1(Pigment)
XX0=<nn>
<nn>:-32 - 0 - + 32
Paper feed adjustment offset
2(Dye)
XX0=<nn>
<nn>:-32 - 0 - + 32
System table version XXS=<mmmmm><n>
<mmmmm>:EG F/W version
User table version XXU=<nn>
<nn>: 00H - FFH
Table1-36. MaintenanceModeSetupItems
Item Panel display Setup value