Service manual

EPSON Stylus Pro 10000/10000CF Revision A
Maintenance
G
eneral Maintenance Issues
2
80
Figure 6-3.
*1 : Confirm that there are dot missing at the time of the nozzle checking pattern printing.
In the case that the abnormality was admitted pushing the cleaning switch for 3 seconds,
and the head cleaning (about 2 minutes : Until the printing passable lamp changes to the
inspection from the flickering) is run. The nozzle checking tries to be run once again
hereafter.
(Good example) (Bad example)
Figure 6-4.
*2 : Use the status sheet as for the confirmation of the part life (the exchange time) that
showed in the Table 6 -2, because the status sheet prints the information that showed in the
Table 6 -3.
Table 6-3. Status sheet
Item Panel display Setting value Contents
Version of the firmware VERSION TOxxxx. yyyy .zzzz
Thefirmwareversionofthe
printer is displayed.
Before page ink used quantity INK xx.x g
The ink used quantity in the page
that printed in immediately
before is displayed.
Printing number of sheets (C).
PRINTABLE SHEET
xxxxxxx sheet
Whether is displayed
additional how many sheets
of printing possibility, on the
basis of the ink used quantity
inthepagethatprinteditin
immediately before every the
ink.
C:Cyan
M:Magenta
LC : Light cyan
LM : Light magenta
Y:Yellow
K: Black
Printing number of sheets (M) PRINTABLE SHEET
Printing number of sheets (LC) PRINTABLE SHEET
Printing number of sheets (LM) PRINTABLE SHEET
Printing number of sheets (Y) PRINTABLE SHEET
Printing number of sheets (K) PAGE COUNT
Accumulation ink consumption
volume
TOTAL INK xxxxxxx.x g
The used quantity of the ink is
displayed with "g" unit.
Accumulation paper
consumption volume
PAPER COUNT xxxxxxx cm
The length of the form that used
it is displayed with "cm" unit.
Ink counter clear
INK COUNTER
CLEAR
Run
The ink counter is initialized in
0.
The consumption volume of the
inkinanoptionalprintedmatter
can be instrumented with [Ink
counter] and [Ink counter clear].
Paper counter clear
PAPER
COUNTER
CLEAR
Run
The form counter is initialized in
0.
The used quantity of the form in
an optional printed matter can be
instrumented with the [form
counter] and [form counter
clear].