Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
75
o
In the case that the parameter of CW is [off], the CCW parameter input screen is
skipped.
o The maximum value of the paper feed is [100.0mm].
o The maximum value of the CR + PF reliability number is [999 times].
o The maximum value of the reliability number designation is [21,600 times].
o Carriage migration MAX location is 738.06 mm from the starting point location.
o Carriage migration MIN location is 111.05 mm from the starting point location.
o When the [Pause] key is pushed during the reliability test, the test can be broken.
o
Following table showing the default value of total reliability test.
5.3.8.12 Life confirmation
Confirm the number of endurance.
You can confirm the endurance record any time because this record is storage in NVRAM.
Following figure showing the reliability number confirmation test menu sequence.
Figure 5-109.
Table 5-23.
Item Default value
CW speed 240 CPS
CCW speed 240 CPS
Feed amount 3.0mm
CR + PF count 500
Life count -1
Item
SelecType
CR Motor : 50
PF Motor : 3
CR+PF Motor : 100
Cutter
Head U/D : 55
HeadLock : 77
Lever Lock : 25
Cleaning : 8
Print Number : 9
Shutter
TotalLife : 30
SelecType
SelecType
SelecType
SelecType
SelecType
SelecType
SelecType
SelecType
SelecType
SelecType
Item
Item
Item
Item
Item
Item
Item
Item
Item
Item