Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
72
5.3.8.8 Cleaning
Perform the cleaning reliability test.
Perform the cleaning designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the cleaning reliability test menu sequence.
Figure 5-105.
o
As for the parameter of cleaning kind, [CL1], [CL1], and [CL2] are possible
select.
o The maximum value of the reliability number designation is [99,999,999 times].
o The maximum value of the wait time is [999 seconds].
o There is the wait time that is designated whenever the cleaning reliability test ends
1time.
Enter
End : 50
LifeCount:-1
Wait Time (Sec).0
Count:10
Cle. Prm. CL1
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter
Enter