Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
71
5.3.8.6 Head lock
Perform the head lock reliability test.
Perform the head lock (cancel / set) designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the head lock reliability test menu sequence.
Figure 5-103.
o
The maximum value of the reliability number designation is [99,999,999 times].
o The maximum value of the wait time is [999 seconds].
o There is the wait time that is designated whenever the head lock reliability test
ends 1 time.
5.3.8.7 Lever lock
Perform the lever lock reliability test.
Perform the lever lock (cancel / set) designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the lever lock reliability test menu sequence.
Figure 5-104.
o
The maximum value of the reliability number designation is [99,999,999 times].
o The maximum value of the wait time is [999 seconds].
o There is the wait time that is designated whenever the lever lock reliability test
ends 1 time.
Enter
Enter
Enter
LifeCount:-1
Wait Time (Sec).0
Count:10
End : 50
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter
Enter
End : 50
LifeCount:-1
Wait Time(Sec).0
Count:10
Adjustable with "Paper Feed +/-" key
Adjustable with "Paper Feed +/-" key