Adjustment
S
elf-Diagnostics
2
70
Figure 5-101.
o
The maximum value of the page size is [3000mm].
o The maximum value of the reliability number designation is [99,999,999 times].
o The maximum value of the wait time is [999 seconds].
o There is the wait time that is designated whenever the cutter reliability test ends 1
time.
5.3.8.5 Head Up / Down
Perform the head up / down reliability test.
Perform the capping designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Moving the carriage and combine the meshing of the gear.
Following figure showing the head up / down reliability test menu sequence.
Figure 5-102.
o
The maximum value of the reliability number designation is [99,999,999 times].
o The maximum value of the wait time is [999 seconds].
o There is the wait time that is designated whenever the head up / down reliability
test ends 1 time.
Enter
Page Size 20mm
LifeCount:-1
Wait Time(Sec).0
Count : 10
End : 50
1
Adjustablewith "Paper Feed +/-" key
at unit of 1%
Adjustablewith "Paper Feed +/-" key
at unit of 1%
Adjustablewith "Paper Feed +/-" key
at unit of 1%
Enter
Enter
Enter
Enter
Enter
Enter
LifeCount:-1
Wait Time (Sec).0
Count:10
End : 50
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.