Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
66
5.3.8.1 CR Motor
Perform the CR motor reliability test.
The carriage runs with the round trip designated number at designated speed.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the CR motor reliability test menu sequence.
Figure 5-98.
o
As for the parameter of CW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
o As for the parameter of CCW, [240CPS], [300CPS], [400CPS], and [800CPS] are
possible select.
o The maximum value of the reliability number designation is [99,999,999 times].
o Carriage migration MAX location is 738.06 mm from the starting point location.
o Carriage migration MIN location is 111.05 mm from the starting point location.
o When the [Pause] key is pushed during the reliability test, the test can be broken.
Enter
Speed CCW : 240CPS
Speed CCW : 240CPS
Life Count
Count : 10
End : 50
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter