Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
49
5.3.4.15 Test pattern print
Print the adjustment pattern and confirm the various adjustment items also input the serial
number.
Following figure showing menu sequence.
Figure 5-76.
o
When push the [Panel setting] key in the serial number input screen, it moves to
the next screen. (When display "No.1:PEG**000000",it moves
"No.2:PEG**000000".)
o When push the [Panel setting] key in the "Print adjustment pattern" display screen,
it moves the serial number input screen "No. 1:PEG**000000".
o When push the [Setting item] key in the serial number input screen, it moves to the
screen of before. (When display "No.2:PEG**000000",it moves
"No.1:PEG**000000".)
o When push the [Setting item] key in the "Print adjustment pattern" display screen,
it moves the serial number input screen "No. 4:PEG**000000".
SelecType
Enter
Enter
Enter
Enter
Enter
Enter
PrintTestPattern
Item
Print : Adj. Variable
No. 1 : PEG**000000
No. 2 : PEG 01**0000
No. 4 : PEG 012345**
No. 3 : PEG 0123**00
Print Adj. Pattern
Printing Pattern
Adjustable with double figure
each by "Paper feed+/-"key.
Shift to the "Head cleaning"
after the print end.
Shift to the "Print test pattern"
with "Enter" key.
Shift to the "Input serial
number" after the print end.
Adjustable with double figure
each by "Paper feed+/-"key.
Adjustable with double figure
each by "Paper feed+/-"key.
Adjustable with double figure
each by "Paper feed+/-"key.