Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
38
5.3.4.6 Test report for dot missing detector
Print out the test result at the end of dot missing detection test.
<Result>
1: Count Value Of detect nozzle.
o 1 234
o Color (K) 45 45 45 45
o Color (C) 45 45 45 45
o Color(LC)45454545
o Color(LM)45454545
o Color (M) 45 45 45 45
o Color (Y) 45 45 45 45
2: Count Value Of dot lost nozzle.
o 1234
o Color(K)0000
o Color(C)0000
o Color(LC)0000
o Color(LM)0000
o Color(M)0000
o Color(Y)0000
Figure 5-57.
C H E C K
P O I N T
n The AGC threshold value are 2208 or more. If the value is less
than 2280, the detector will judge the no dot missing even if the
dot missing happen.
n DAC: D/A convertor
n DAC max. : Maximum input value of detector at dot missing
detection.
n DAC min. : Minimum input value of detector at dot missing
detection.