Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
35
n
Cursor move to the right edge when you press the "Item" key at the left edge.
n
Cursor skip the space area.
n
When the [Enter] key is pushed with [Head * -1]-[Head * -4], display moves to
the menu next to 1 hierarchy.
n
When the [Enter] key is pushed with [Head * -5], rank of the head is settled.
n
After the code of the Head 1 or the Head 2 is input, display moves to [Head 2 code
input] or [Head 3 code input] individually.
n
After the ink fill, display moves to the top menu of the adjustment.
n
When the [Pause] key is pushed, display moves to the menu next to 1 hierarchy.
At this time, pay attention the code that input is not settling, although it is
effective
n
The migration of the cursor is skipped in the display item of [
\
].
5.3.4.4 Head nozzle check
Ensure the dot nozzle operation with test print sample.
If the nozzle injection is not perfect, perform the head cleaning several times.
Ink cartridge replacement message will appear when the ink cartridge is empty.
Print out sample is shown on the Figure 5-53, Figure 5-54 and Figure 5-55 .
Following figure showing the nozzle check menu sequence.
Figure 5-51.
Printing Pattern
Authen. Head Rank?
Wait
Pause key Chk. End
Wait
Enter
Return to "
Nozzle Check End
"
with "Pause" key.
Print End
Print Movement End
Pause
Print Movement End
1