Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
18
o
"INK NOT xxxxxx" : Display of "xxxxxx" means ink cartridge name with
symbolic code.
o "EdgeAD xxxyyy"/"FrontAD xxxyyy/"RearAD xxxyyy" :
: Display of "xxx" means difference from ON minus Off, "yyy" means ON level.
Following figure showing the relation of sensor display and sub tank ink amount.
Figure 5-22.
o
"F" will display when the overflow condition is presented.
o "Laser xxxx" :Display
of "xxx" means AGC thresh hold value. If the value is less than
"2208" you need to replace the dot missing detector unit.
5.3.3.5 Encoder
Display the CR and PF encoder value.
Following figure showing the encoder test sequence.
Figure 5-23.
Display unit is the number of encoded pulse.
Encoder : CR xxxx
Encoder : PF xxxx
Item
Item
0000
FFFF
Select Type