Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment Adjustment Steps
2
02
Figure 5-11. VR layout
6. Confirm the value with sheet set is within the ON value (Right value).
EDGE SENSOR
1. Remove the rear cover.
2. Set the adjustment sheet normally. (Refer to Table 5-4, “Test sheet and Adjustable
VR,” on page 201.)
3. Enter the Self-diagnostic mode. (Refer to “Start-up procedure” on page 213.)
4. Select "Test"/"Sensor"/"EdgeAD" by panel operation. (Refer to “Sensor” on
page 217.)
5. Take the carriage and move on the paper manually.
6. Adjusting VR 3 or VR6 (Refer to “VR layout” on page 202.) , the ON-value (Right
value) becomes within the adjustment range. (Refer to Table 5-5, “Adjustment
Range,” on page 202.)
7. Confirm the value with sheet set is within the ON-OFF value (Left value).
Table 5-5. Adjustment Range
Sensor Left (ON-OFF) Right (ON)
P_Front 040 - 04A 040 - 05E
P_Rear 040 - 04A 040 - 05E
P_Edge 0B0 - 0CF 0C0 - 0CF
VR5
VR4
VR2
VR3
VR6