Service manual

EPSON Stylus Pro 10000/10000CF Revision B
Adjustment Adjustment Steps
2
01
5.2.3.9 Offset adjustment for dot missing detector
Automatically determined offset value after the dot missing detection operation. Refer to
the paragraph Offset adjustment for dot missing detectoron page 201 for details.
5.2.3.10 P_Front/Rear/Edge sensor adjustment
P_FRONT/REAR SENSOR
1. Remove the rear cover.
2. Set the adjustment sheet normally. (Refer to Table 5-4, Test sheet and Adjustable
VR,on page 201.)
3. Enter the Self-diagnostic mode. (Refer to Start-up procedureon page 213.)
*:Blight Recycle Paper (XEROX) is soled in japanese market only.
4. Select "Test"/"Sensor"/"FrontAD" or "Test"/"Sensor"/"Rear" by panel operation.
(Refer to Sensoron page 217.)
5. Adjusting each VR (Refer to VR layout on page 202.) corresponding to the each
sensor, the ON-OFF value (Left value) becomes within the adjustment range. (Refer to
Table 5-5, Adjustment Range, on page 202.)
C A U T I O N
n Performing these adjustment, set the H top cover and front cover
preventing from outside light exposing.
n Set the paper set lever after adjustment sheet setting.
Table 5-4. Test sheet and Adjustable VR
Sensor Adjustment sheet Rough adjustment Fine adjustment
P_Front
KIMOTO #300
Tracing Paper
VR2 VR5
P_Rear
KIMOTO #300
Tracing Paper
VR1 VR4
P_Edge
Blight Recycle Paper
(XEROX)*
VR3 VR6