Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment Adjustment Steps
2
00
5.2.3.7 T fence and CR encoder position adjustment
<Adjustment procedure> Use the CR_ENC setting tool.
1. Remove Panel ASSY and side cover R/L.
2. Remove H top cover.
3. Connect the Panel ASSY again.
4. Select the "Test: Sensor" from the diagnostic mode and place the carriage to the
center.
5. Loosen two of CR_ENC sensor fixing screws on the carriage.
6. Mount the CR_ENC setting tool and adjust the position then tighten the screws.
7. Move and place the carriage to the middle of CR guide rail.
8. Escape from the "Test: Sensor" mode.
9. Turn off the printer power after the initialization.
10. Attach the cover which are removed with step 1 and 2.
Figure 5-8.
5.2.3.8 Head slant adjustment
Refer to “A13 slant adjustment” on page 239 to “B123 slant adjustment” on page 241 for
standard and procedure. Loosen two screws then adjust the head slant with adjustment lever
which are shown below. Secure the screws after the adjustment.
Figure 5-9.
Figure 5-10.
Adjustment lever