Service manual
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment Adjustment Steps
1
97
5.2.3.2 PF timing belt tension adjustment
This adjustment is apply to all the work with PF timing belt detachment such as PF motor
removal etc., Confirm that is specified tension at the time of PF timing belt installation.
Standard:
3.5 kg
+/-10%(The tension toward PF motor fixing bracket)
<Adjustment procedure>
1. Remove the side cover L. (7 screws)
2. Loosen 4 screws on the PF motor fixing bracket.
3. Hook the tension gauge to the PF motor shaft.
4.
Hooks the
tension gauge and
keep the tension within 3.5 kg+/-10% then fix the
motor fixing bracket
with four screws.
5. Attach the cover which are removed with step 1.
Figure 5-3. PF timing belt tension adjustment
5.2.3.3 P_THICK sensor fixing bracket adjustment
When you change the position of fixing bracket, perform the following adjustment with
self-diagnostic function.
Standard: 0.6mm: Thin
paper determination
/0.7mm:Thick paper
determination
<Adjustment procedure>
1. Remove the H top cover (6 screws).
2. Select the "Test: Sensor" from the diagnostic mode and performs "Paper Thickness".
3. Place the long hand side of filler gauge between the right edge of detection roll and
sub_platen.Adjust the fixing position which obtains "Thick paper" with
0.7 mm gauge
and "
thin
paper" for 0.6mm.
4. Attach the H top cover which are removed with step 1.
Figure 5-4. P-Thick sensor adjustment
PF timing belt
P_THICK sensor