Service manual
EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
83
4.2.3.23 Removing the P_REAR Sensor ASSY
1. Remove the R Side Cover as described in “R Side Cover Removal 124.
2. Remove the L Side Cover as described in “L Side Cover Removal 124.
3. Remove the H Top cover as described in “H Top Cover Removal 123.
4. Remove the Rear Cover as described in“Rear Cover Removal 126.
5. Remove the Paper Guide U as described in “Removing Paper Guide U 131.
6. Disconnect the cable for the P_REAR Sensor ASSY from its connector CN44 on the
C362MAIN board.
7. Remove the two screws (CBS M2x6) securing the Paper Rear Sensor, and remove it.
Figure 4-167.
8. Release the harness for the P_Rear Sensor ASSY from the cable clamps.
NOTE: When removing/installing the Paper Guide U, be careful not to mar the
P_REAR Sensor ASSY with the edge of the sensor inspection window.
NOTE: P_REAR Sensor ASSY position is adjusted at factory. Therefore, be sure
to mark its current position before removing the screws.
4.2.3.24 Removing the Front Cover Sensor ASSY
1. Perform the Steps 1 to 11 in “Front Cover Removal” (Paragraph “Front Cover
Removal 130.)
Front cover sensors are built in the both hinge unit.
Figure 4-168.
Paper Guide U
Paper_Rear sensor
Screw
(Without Paper Guide U)
A D J U S T M E N T
R E Q U I R E D
If you replace the P_REAR Sensor ASSY, perform the necessary
adjustment listed in Chapter 5.
Front
Cover
Sensor L
Left hinge unit
Right hinge unit