Service manual
EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
73
4.2.3.14 Removing the Suction Control Motor
1. Disconnect the cable connector connected to CN14 on the C362DRV board.
Figure 4-138.
2. Marking the suction control motor fixing position.
3. Remove two screws fixing the suction control motor, then remove it.
Figure 4-139.
4.2.3.15 Removing the Ink Pump ASSY
1. Remove the Cleaning Unit as described in “Removing the Cleaning Unit” (“Removing
the Cleaning Unit 167.)
2. Disconnect the cables for the ink release plunger and Ink Pump Motor from its
connector CN11 / 25 on the main board, and take the cable out from the hole in the R
side frame.
3. Disconnect the cable from sensor connector.
Figure 4-140.
Suction control
motor
Cables
(connected to CN14
on the C362DRV
board)
Suction control
motor
Screw
Dot missing
detector
Air release
plunger cable
Ink motor cable
Ink pump motor