Service manual
EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
72
5. Disconnect the cable for the panel unit from the cable clump on the Dot missing
detector.
Figure 4-136.
6. Hold the Dot missing detector with your hand then remove the two screws (
:M4x8) securing the Dot missing detector to the CR guide rail, then remove the Dot
missing detector.
Figure 4-137.
Cable clump
Cableforthepanel
unit
Dot missing
detector
CR Guide rail
Screw
C A U T I O N
When secure the screw, pay attention so as not to drop the screw into
the CR guide rail by using the magnet driver. (It is because be not
seen the place when the screw is dropped into the CR guide rail.)
Do not scar the steel belt.