Service manual
EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
65
5. Fully slide the PF motor backed to the PF Polly side as shown with arrow direction.
Figure 4-117.
6. Remove the two (CP(W) M3x8) screws securing the PF Motor ASSY to the PF motor
bracket, and then remove the PF motor bearing, from the bracket.
Figure 4-118.
Screw
Screw
PF Motor bracket
PF timing belt
Screw
C A U T I O N
When assembling the PF Motor ASSY, move the PF timing belt
manually and check that the PF timing belt revolves around the center
of the reduction pulley. When removing / installing, do not bend or
injure the PF scale.
Figure 4-119.
A D J U S T M E N T
R E Q U I R E D
If you remove the PF motor, make the necessary adjustments listed in
“PF Timing Belt Tension Adjustment”
PF loop scale
Steel belt
Timing belt