Service manual
EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
46
4.2.3.2 Removing the Suction Fans
1. Move the head carrige to the home position.
2. Remove three screws (M3x8) on the clamp securing the head cables and tubes.
3. Unlock the tube clamp
from guide rail.
4. Remove four screws (M3x8) on the guide rail.
5. Remove the guide rail.
Figure 4-70.
Guide rail
Screw
Clamp
Tube clamp
(Front side view)
(Left side view)