Service manual
Product Description
1-12
EPSON FX-880/FX-1180 Service Manual
Table 1-17. Electrical Specifications for the UPS Version
Item Specification
Rated voltage 100 to 120 VAC or 220 to 240 VAC
Input voltage range 90 to 132 VAC or 198 to 264 VAC
Rated frequency range 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Rated current at 120 V: 0.8 A (maximum 2.0 A, depending on the character type)
at 230 V: 0.5 A (maximum 1.0 A, depending on the character type)
Power consumption FX-1180: Approximately 36 W (ISO/IEC 10561 letter pattern)
FX-880: Approximately 34 W (ISO/IEC 10561 letter pattern)
ENERGY STAR Compliant
Insulation resistance
10 MΩ minimum (between AC line and chassis)
Dielectric strength 1500 VAC rms 1 min (between AC line and chassis)
Reliability
Table 1-18. Reliability Statistics
Item Specifications
Total print volume 6.5 million lines (except printhead)
MTBF 4000 power-on hours (POH)
Printhead life 200 million characters/wire
Environmental Requirements
The printer requires the following conditions while operating or in storage:
Table 1-19. Environmental Requirements
Item Specifications
Temperature
41 to 95° F (5 to 35° C), operating
*1
59 to 77° F (15 to 25° C), operating
*1, *2
-22 to 140° F(-30 to 60° C), storage
Relative Humidity 10 to 80%, operating
*1
30 to 60%, operating
*1, *2
0 to 85%, storage
*1
Notes:
1. Without condensation.
2. During printing on envelopes, card stock, labels, multi-part forms, roll paper, or recycled paper.