Specifications

EPL-5700 Chapter4 Disassembly and Assembly
Rev. A
4-2
2
CHECK POINT
9
Face down the sharp side of the separation
claws as it is shown in Figure4-28, when
removing or installing them.
Lay the harness of the thermister, as it is shown
figure4-29.
Harness of the Thermister
Back side of the fusing unit
Figure 4-29. Locating Harness of the Thermister
4.2.17.3 Paper Eject Sensor(PS3)
1. Remove the fusing unit. (See section 4.2.16)
2. Release the connection between the sensor and lever, moving the lever
of the paper eject sensor.
3. Release the hook of sensor securing the sensor to the fusing unit, and
remove the sensor.
Sensor Lever
Sensor Hook
Paper Eject Sensor
Figure 4-30. Paper Eject Removal