Specifications

REV.-B
(80-column):
1) 13 mm (0.51 in.) or more when a paper width of 101 mm (4 in.) to 241 mm (9.5 in.) is used.
24 mm (0.9
in.)(rear insertion)\ 26 mm (1.0 in.)(front/bottom insertion) or more when a paper width
of 254 mm (10 in.) is used.
(1 36-column):
13 mm (0.51 in.) or more when a paper width of 101 mm to 401.3 mm (4 in. to 15.8 in.) is used.
15 mm or more when a paper width of 381 mm to 406 mm (15 in. to 16 in.) is used. 13 mm (rear
insertion) (0.5 1 in.) /1 7 mm (front/bottom insertion) (0.67 in.) is used. ( 136-column).
Ink ribbon
Type #7753 black ribbon cartridge (80-column)
#7768 film ribbon cartridge (80-column)
#7754 black ribbon cartridge (1 36-column)
#7770 film ribbon cartridge (1 36-column)
Color Black
Life 2 million characters at 48 dots/character (black ribbon)
(80-column) 0.2 million characters at 48 dots/character (film ribbon)
(136-column) 0.3 million characters at 48 dots/character (film ribbon)
Dimensions of ribbon cartridge
Fabric Type:
(80-column): 293 mm (W) X 34 mm (H)
X 72 mm (D)
(136-column): 468.3 mm (W) X 34 mm (H) X 72 mm (D)
Film Type:
(80-column): 293 mm (W) X 34 mm (H) X 72 mm (D)
(136-column): 468.5 mm (W) X 34 mm (H) X 72 mm (D)
Mean cycles between failures
(MCBF) 3 million lines (excluding printhead)
Mean time between failures
(MTBF) 4000 power on hours (POH) (25% duty)
200 million strokes (black ribbon)
100 million strokes (film ribbon)
Safety standards UL1 950 with D3 (U.S. version)
CSA22.2#220
EN 60950 (TUV) (European version)
Radio frequency interference
(RFI)
FCC class B (U.S. version)
VDE0871 (self-certification) (European version)
Reliability
Life of
printhead
Safety approvals
Electrical specifications
120 V version
Rated voltage
Input voltage range
Rated frequency
Input frequency
Rated current
Power consumption
insulation resistance
Dielectric strength
120
VAC
103.5 to 132
VAC
50 to 60 Hz
49.5 to 60.5 Hz
2.0 A
Approx. 33 W (during a
self-
test in draft mode, 10 cpi)
10 megohms, minimum (at 500
VDC between AC line and
chassis).
1000
VAC rms for 1 minute or
1200
VAC rms for 1 second
(between AC line and chassis)
1-7