Service manual

EPSON Stylus
&2/25
1520
Rev. A
3-2
4
3.2.10.8 Pump Unit Removal
1. Remove the printer mechanism unit. (Refer to Section 3.2.6.)
2. Remove the paper eject frame. (Refer to Section 3.2.10.7.)
3. Remove 2 screws (CBS, 3X6 and CBP, 3X8) securing the pump unit to the printer mechanism unit.
Then remove the pump unit.
;
When mounting the head cleaner onto the pump unit, set the rubber part of the cleaner facing to
the pump side.
Head Cleaner
Pump Unit
Right Frame Assembly
Screw (CBP 3X8)
Middle Frame Assembly
Head Cleaner Lever
Screw (CBS 3X6)
Figure 3-21. Pump Unit Removal
WORK POINT