1.2.10 Electric Specifications
120 V version
Rated voltage :AC 120 V
Input voltage range :AC 103.5 to 132 V
Rated frequency renege :50 to 60 Hz
Input frequency range :49.5 to 60.5 Hz
Rated current :0.7 A (maximum)
Power consumption :Approximately 21 W (ISO/IEC 10561 Letter pattern)
Conforms to Energy Star program
Insulation resistance :10 M ohms min. (Between AC line and chassis, DC 500 V))
Dielectric strength :AC 1,000 V rms. (1 minute) or AC 1,200 V rms. (1 second)
(Between AC line and chassis)
220 - 240V version
Rated voltage :AC 220 to 240 V
Input voltage range :AC 198 to 264 V
Rated frequency renege :50 to 60 Hz
Input frequency range :49.5 to 60.5 Hz
Rated current :0.4 A (maximum)
Power consumption :Approximately 21 W (ISO/IEC 10561 Letter pattern)
Conforms to Energy Star program
Insulation resistance :10 M ohms min. (Between AC line and chassis, DC 500 V)
Dielectric strength :AC 1,500 Vrms. (1 minute) (Between AC line and chassis)
1.2.11 Environmental Conditions
Temperature
Operating*
1
:10•• to 35••
Non operating*
2
:-20•• to 40•• ( 1 month at 40••)
-20•• to 60•• (120 hours at 60••)
Humidity
Operating*
1
*
3
:20% to 80% RH (without condensation)
Non operating*
2
*
3
:5% to 85% RH (without condensation)
Resistance to vibration
Operating :0.15 G
Non-operating*
2
:0.50 G
Resistance to shock
Operating :1 G within 1 ms
Non-operating*
2
:2 G within 2 ms
*1 :Refer to the table below for guaranteed range.
*2 :In shipment container.
*3 :Without condensation
90
80
70
60
50
40
30
20
10 20
27
30
35
40
Temperature ( )
Humidity (%)
(80 H)
(95 H)
(50 H)
C
C
C
C
C
C
C
Figure 0-7. Environmental Conditions