User Manual

Table Of Contents
o
Is the original loaded with skew?
Reload the original. If the original is loaded with
skew, it cannot be fed properly.
Scanned Image Is Misaligned
o
Change the direction that the original is
loaded.
Changing the direction that the original is loaded
may improve scan results.
o
Is the original curled?
If the original is curled, smooth out the original and
place it flat. Then scan the original.
o
Try Image Stitching Adjustment.
Doing Image Stitching Adjustment may improve
scan results.
U “Lines Appear on Scanned or Copied
Documents” on page 209
o
Try using the optional carrier sheet.
Putting the original into the carrier sheet smooths
out any wrinkles and may improve scan results.
Document Feed Adjustment
If the print results and the length of the original of
copied or scanned files do not match, use the
following procedure to do Document Feed
Adjustment. If you want to shorten the length of the
print out, press the minus button. If you want to
lengthen it, press the plus button. Differences in
length may occur due to the type of paper used for
printing.
A
Touch Settings on the Home screen.
B
Touch, in order, General Settings - Scan
Settings - Scan Options - Document Feed
Adjustment.
The adjustment value settings screen appears.
The adjustment values are shown in %.
C
Either touch - or + to show the intended
adjustment values or touch the adjustment
entry area to enter the adjustment values via
the keyboard screen.
Adjustment values are determined as shown
below.
Example) When the length of the original is 50
cm and the print result is 50.1 cm:
50/50.1×100-100= -0.1996, rounded at the
second decimal.
Adjustment value: -0.2
D
Touch OK.
Image Stitching Adjustment
As for the original ( ) shown in the figure below, if
a misalignment occurs in the scanned image, such as in
, do Image Stitching Adjustment using the
following procedure.
The arrow in
indicates the feed direction of the
original.
A
Touch Settings on the Home screen.
B
Touch, in order, General Settings - Scan
Settings - Scan Options - Image Stitching
Adjustment.
The adjustment value settings screen appears.
C
Either touch - or + to show the intended
adjustment values or touch the adjustment
entry area to enter the adjustment values via
the keyboard screen.
Shifting the adjustment value by 1 will correct
the misalignment by about 0.1 mm in the
actual size.
SC-T5400 Series/SC-T5400M Series/SC-T3400 Series/SC-T3400N Series User's Guide
Problem Solver
212