user manual
DFX-8500
Rev. B
3-2
6
3.2.4.6 AC Inlet Removal
Step 1: Remove the C204 power supply board assembly. (Refer to Section 3.2.4.2)
Step 2: Remove the C204 MAIN board assembly. (Refer to Section 3.2.4.5)
Step 3: Remove the three CBB (M3x8) screws and one CB (O) (M4x6) screw securing the grounding
plate to the bottom panel assembly and remove the grounding plate.
CBB(M 3X8)
Bottom P anel Assem bly
G rounding Plate
CB(O)
(M 4X6)
A C In le t S e t
Figure 3-35. Grounding Plate Removal
Step 4: Remove the two CFS (M3x10) screws securing the AC inlet to the grounding plate and remove
the AC inlet.
A C In le t S e t
G rounding
Plate
CFS(M 3X10)
Figure 3-36. AC Inlet Removal