Service manual
Stylus Photo R1900/R2880/R2000 Revision E
Stylus Photo R2000 Adjustment 195
Confidential
Colorimetric Calibration
The procedure of this adjustment is same as Stylus Photo R1900 /
R2880. Refer to "5.2.4 Colorimetric Calibration"
(p.153). But, support
paper for Calibration Chart is different from the previous models.
Table 8-18. Support Paper for Colorimetric Calibration
Multi Sensor Adjustment (Ink Mark Sensor Adjustment)
1. Print the Nozzle Check Pattern to check not to appear dot missing.
2. Click the “Adjustment” Button. The program automatically adjust the Ink
Mark Sensor. (Program prints the pattern for adjustment. It's not for
checking.)
3. Print the check pattern by clicking the "Check" Button.
4. The upper side of the pattern don't have a dot missing.The lower side of the
pattern have eight dot missings on purpose. Confirm the dot-missing
counts of these patterns.
Purpose Paper
Nozzle Check Pattern Plain Paper
Calibration Chart Premium Presantation Paper Matte
Matte Paper Heavy-weight (Epson Matte)