Service manual
EPSON Stylus Photo R1900/R2880/R2000 Revision E
Disassembly And Assembly Removing the Sensors 135
Confidential
4.6.5 PE Sensor Holder
1. Remove the APG Assy. (p.89)
2. Remove the PE Sensor connector cable from the five tabs on the Release Holder
Assy and the two tabs on the Head Cable Cover.
Figure 4-171. Releasing the Cables
3. Release the tabs that secure the PE Sensor Holder from the notch on the Main
Frame with a flathead screwdriver, and slide the PE Sensor Holder upwards and
then remove it toward you.
Figure 4-172. Removing the PE Sensor Holder
Tabs
PE Sensor connector cableTabs
Release Holder Assy.
Head Cable Cover
PE Sensor Holder
Front Side
Tab
Align the four tabs and guide pin on the PE Sensor Holder with the
positioning holes on the Main Frame correctly so that there is no
gap between the PE Sensor Holder and the Main Frame.
Figure 4-173. Reinstalling the PE Sensor
Tabs
Guide
Guide pin