Service manual

EPSON Stylus Photo R1900/R2880/R2000 Revision E
Disassembly And Assembly Removing the Motors 131
Confidential
4.5.3 ASF Motor
1. Remove the ASF Assy. (p.106)
2. Release the ASF Motor cable from the cable hook and disconnect the relay
connector.
3. Remove the two C.B.P. M3 x 8 screws that secure the ASF Motor and remove the
ASF Motor.
Figure 4-163. Removing the ASF Motor
Secure the grounding wire and the ASF Motor together with the
screw in the middle of the printer.
Cable Hook
ASF Motor
4) C.B.P. M3x8
Grounding Wire