Service manual

Paper-pickup assembly
1 Remove the following assemblies.
Right-side cover. See
Right-side cover on page 75.
Left-side cover. See
Left-side cover on page 77.
Top-cover assembly. See
Rear panel and top-cover assembly on page 77.
Transfer roller. See
Transfer-roller assembly on page 84.
Fuser (fixing) assembly. See
Fuser (fixing) assembly on page 89.
2 Disconnect and unwind any additional wires as necessary to release the paper-pickup assembly.
Unplug and unwind the wire from the solenoid to the formatter.
CAUTION Do not pull directly on the wires when a connector is disconnected. Always pull
on the plastic body of a connector to avoid damaging the connector wires.
3 Remove six screws (callout 1), and then remove the paper-pickup assembly.
1
Figure 5-28 Remove the paper-pickup assembly
Reinstallation tip When replacing the paper-pickup assembly, be sure to transfer the
sensor PCB and, if necessary, the separation-pad assembly to the new paper-pickup
assembly.
ENWW Internal assemblies 91