Service manual
4 Remove three screws (callout 2). (This figure shows the delivery-sensor PCB removed, but it is not
necessary to remove this PCB in order to remove the fuser).
2
Figure 5-27 Remove the fuser (fixing) assembly (2 of 2)
5 Lift the end of the fuser assembly from the right side of the printer, and remove it.
Reinstallation tip When replacing the fuser assembly, be sure to transfer the delivery sensor
PCB from the old fuser to the new one.
NOTE When reinstalling the fuser assembly, be careful not to break the plastic tab on the
assembly.
90 Chapter 5 Removal and replacement ENWW