User Manual

52
Battery Control Parameters
All the coefficient is referred to 25, and twice in 24v system rate, triple in 36v system
rate and quadruple in 48v system rate.
Battery Type
Gel
Sealed
Flooded
User
High Volt Disconnect
16V
16V
16V
9~17V
Charging limit voltage
15V
15V
15V
9~17V
Over Voltage Reconnect
15V
15V
15V
9~17V
Equalization voltage
——
14.6V
14.8V
9~17V
Boost voltage
14.2V
14.4V
14.6V
9~17V
Float voltage
13.8V
13.8V
13.8V
9~17V
Boost return voltage
13.2V
13.2V
13.2V
9~17V
Low voltage reconnect
12.6V
12.6V
12.6V
9~17V
Under voltage recover
12.2V
12.2V
12.2V
9~17V
Under voltage warning
12V
12V
12V
9~17V
Low voltage disconnect
11.1V
11.1V
11.1V
9~17V
Discharging limits voltage
10.6V
10.6V
10.6V
9~17V
Equalize duration
——
120min
120min
0~180min
Boost duration
120min
120min
120min
10~180min
The following rules must be observed when modify the parameters value in user battery
type(factory default value is the same as sealed type):
Rule1: High Volt Disconnect > Charging limit voltage Equalization voltage
Boost voltage Float voltage > Boost return voltage;
Rule2: High Volt Disconnect > Over Voltage Reconnect;
Rule3: Low voltage reconnect > Low voltage disconnect Charging limit voltage
Rule4: Under voltage recover > Under voltage warning Charging limit voltage;
Rule5: Boost return voltage > Low voltage reconnect