5.3 Maintenance
The following inspections and maintenance tasks are recommended at least two times per
year for best performance.
Check that the air flow and ventilation around the controller is not blocked. Clear all
dirt or fragments on the heat sink.
Check all the naked wires to make sure insulation is not damaged for serious
solarization, frictional wear, dryness, insects or rats etc. Maintain or replace the wires if
necessary.
Check and confirm that LED or LCD is consistent with required. Pay attention to any
troubleshooting or error indication .Take corrective action if necessary.
Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
Confirm that all the terminals have no corrosion, insulation damaged, high temperature
or burnt/discolored sign, tighten terminal screws to the suggested torque.
Inspect for dirt, insects and corrosion, and clear up.
Check and confirm that lightning arrester is in good condition. Replace a new one in
time to avoid damaging of the controller and even other equipments.
NOTE: Dangerous with electric shock!
Make sure that all power source of controller is cut off when operate
above processes, make inspection or other operations!