User Manual

48
Discharging circuit is off
and the LOAD monitor
shows Short.
Load circuit is
short
Please check carefully loads
connection; It is reactivated after
delayed 5 seconds for the first time,
10 seconds for the second time, 15
seconds for the third time, 20 seconds
for the fourth time and 25 seconds for
the fifth time. If over 5 times, push
the ENTER key and controller
recover output after 10 seconds. In
the process of 5-time reactivation, if it
is recovered manually, the 5-time
reactivation will be circulated again.
When there is any change from night
to daytime, restart the self-recovery
process. Namely, 5-time circular
reactivation can be operated again.
Charging and discharging
circuit is off and the
LOAD of monitoring
interface shows MOS-I
ShortError.
Electronical
component
damaged.
Please restart controller, if the fault
still exists, cut off charging and
discharging circuit immediately and
contact the supplier to make
maintenance.
Charging and discharging
circuit is off and the
LOAD monitor shows
Over Temp.
controller is over
temperature
When the temperature of controller
exceeds 85, the controller will cut
input and output circuit. when it is
below 75,the controller will
automatically reconnect input and
output circuit.