User Manual

38
When updating successfully, the prompt will show below and then move back to the main
menu.
Nominal Parameter Interface
press or , move inverse cursor to 5Rated Value, then press
button to enter into nominal parameter interface below. Battery rate and
capacity can be modified. the batter rate are 12v, 24v, 36v, 48v or auto. Battery capacity
ranges from 1 to 9999AH in the interface,. Press or to
increase or decrease the value.
If changing the value, press to submit and the following message will
prompt: Press or to select ―save‖ to confirm update or cancel.
After confirmed, the cursor will move back to the main menu.
Time Control 2
On Time : 19 : 20 : 00
Off Time : 07 : 00 : 00
Single Double
SAVE SUCCESS
Rated Value
Batt : 12.0 V 0070AH
Load : 10.0A PV : 10.0A
Type : Gel