User Manual
36
NOTE: When the “OFF” time is later than local sunrise time, the
controller will turn off the load output at the sunrise time, because
light control’s priority level is higher!
▼ Time control interface
When the inverse cursor rests on Time in the time control interface, press to
enter into time control interface. Press or to modify all
parameters of time interval 1.
When is continuously pressed, it will enter into the following interface.
Press or , the inverse cursor moves among every parameters.
Press or to modify value of time interval 2. When choosing
Double time control mode, the load output will accord to time1 and time2.
Light On + Timer
On : 06.0 V Delay :10 m
Off : 05.0 V Delay :10 m
Work Time : 10 : 00 : 00
SAVE SUCCESS!
Time Control 1
On Time : 07 : 20 : 00
Off Time : 15 : 00 : 00