User Manual
28
Charging and Discharging Parameters Setting Interface
press to enter into charging and discharging parameters setting interface as
inverse cursor at 3.Parameter Set in main menu 1. press , it moves back
to the previous interface and the inverse cursor points to the position of the first parameter.
The following control voltage parameters value must be between 9v and 17v and in
strictly accordance with: High Volt Disconnect > Charging limit voltage ≥ Equalization
voltage ≥ Boost voltage ≥ Float voltage > Boost return voltage; High Volt
Disconnect > Over Voltage Reconnect; Low voltage reconnect > Low voltage disconnect
≥ Charging limit voltage; Under voltage recover > Under voltage warning ≥
Charging limit voltage; Boost return voltage > Low voltage reconnect;
▼ Temperature compensation coefficient
Press or , then the inverse cursor moves among every
parameters sequencely. Press or to modify temperature
compensation coefficient.
Parameter Set
Temp Compensate Coeff
-03.0mV / ºC / 2V