User Manual

26
Discharging energy statistics
Device Setting
In the main menu, press or button to make the inverse cursor
point to 2Device Set, press to enter device setting interface which displays
the following contents. When setting in this interface, real time clock will stop running.
Please correct real time clock again after parameters are changed.
In the interface, press or , the inverse cursor moves among
every parameter. Pressing button could move the inverse cursor back to
main menu. When inverse cursor points at the parameter, the contents of the parameter
can be modified. press to increase the value and press to
decrease the value. LCD backlight auto-off time can be set between 00 ~999 seconds.
The below message box will be prompted after press . Press
or to choose save or cancel operation. When modification canceled, the
interface will go back main menu.. Auto-off time of LCD backlight is 60 seconds as
default.
Device Set
Date : 12 05 - 2011
Time : 12 : 24 : 23
Device Set
ID: 001
Backlight: 010 sec
Disch. Energy
Day: 0.75KWh
Mon: 18.53KWh
Total: 54.32KWh