User Manual
19
Parameter
Detail
Note
Working
Time 1
The open time of load in the light mode
after dusk
The value is set to ZERO
means the controller will
not work at this working
time period; the actual
time of load-on is relative
with night time, working
time1 and working time2
Working
Time 2
The open time of load in the light mode
before dawn
Night time
The controller calculated the total
length of the night by self-learning. The
time should be more than 3 hours
4. Timer
The mode includes single and double time intervals. Set the starting and ending time for
each time interval and controller works according to the set time interval.
Parameter
Detail
Time Control 1
Set the begin and end time 1 of the load output
Time Control 2
Set the begin and end time 2of the load output
Single
The load output according to time1
Double
The load output according to time1 and time2
● Device Parameters
Parameter
Detail
ID
Range: 1 - 200
Clock
Format:dd-mm-yyyy hh-mm-ss
Password
Default: 000000