User Manual
21
Main Menu
There are 9 interfaces for monitoring, as shown in the below picture.
Press button to move inverse cursor among 9 menus.
1.Monitoring
2.Log Info
3.Clock Set
4.Local Para Set
5.Load Set
6.Control Para
7.Sys Password
8.Default Set
9.Load Set
Monitor
There are 11 interfaces for monitoring, as shown below:
Batt Volt.
12.4V
Batt Cur.
2.2A
Batt Day’Max
13.5V
Batt Day’Min
11.7V
Batt State
Normal
Charge State
Float
PV Volt.
25.4V
Generated Energy
1.5kWh/D
PV Power
85.5W
Consumed Energy
1.1kWh/D
Load Power
30.5W
Total Generated
7.50kWh
Total Consumed
5.50kWh
Batt Temp
21ºC
Temp Coefficient
-3mV/ºC/2V
Load Volt.
12.4V
Load Cur.
2.2A
Load State
ON
Local Temp
25.5 ºC
The parameters in monitoring interface are only for browse.
Press button to browse the parameters interfaces in turns.
There are 5 battery status: Normal, UVW(Under voltage warning), LVD(Low
voltage disconnect), Over Voltage, Over Temperature and 4 charging stages:
no charging, equalized, boost, float.