User Manual

16
Model
Max. PV input current
Max. PV wire size
IT4415ND
45A
16mm
2
/6AWG
IT6415ND
60A
16mm
2
/5AWG
NOTE: When the PV modules connect in series, the open circuit voltage of the
PV array must not exceed 138V (25)
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference
size as below:
Model
Rated charge current
Battery wire size
Load wire size
IT4415ND
45A
16mm
2
/6AWG
16mm
2
/6AWG
IT6415ND
60A
16mm
2
/5AWG
16mm
2
/5AWG
NOTE: The wire size is only for reference. If there is a long distance between
the PV array and the controller or between the controller and the battery, larger
wires can be used to reduce the voltage drop and improve performance.
WARNING: Risk of electric shock!
Use fuses or breakers in solar and battery circuits is recommended
and make them keep OFF state before connection.
WARNING: Risk of electric shock!
Exercise caution when handling solar wiring. The solar PV array can
produce open circuit voltages in excess of 150 V when in sunlight.
Pay more attention to it.
WARNING: Risk of explosion or fire!
Never short circuit battery positive (+) and negative (-) or cables.
Pay more attention to it
AVERTISSEMENT : Risque d'électrochoc!
L'utilisation de fusibles ou coupe-circuits dans le module solaire, le
chargeur et les circuits de la batterie est recommandée, ils doivent
être tenus en position éteinte avant la connexion.
AVERTISSEMENT : Risque d'électrochoc!
Faites attention lors de la manipulation des connexions solaires. La
matrice PV solaire peut produire des tensions supérieures à 150V, à
la lumière du soleil. Soyez particulièrement attentif à cela.
AVERTISSEMENT : Risque d'explosion ou d'incendie!
Ne court-circuitez jamais les pôles positifs (+) et négatifs (-) de la
batterie ou les câbles. Soyez particulièrement attentif à cela.