User Manual
16
Model
Max. PV input current
Max. PV wire size
IT4415ND
45A
16mm
2
/6AWG
IT6415ND
60A
16mm
2
/5AWG
NOTE: When the PV modules connect in series, the open circuit voltage of the
PV array must not exceed 138V (25℃)
Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference
size as below:
Model
Rated charge current
Battery wire size
Load wire size
IT4415ND
45A
16mm
2
/6AWG
16mm
2
/6AWG
IT6415ND
60A
16mm
2
/5AWG
16mm
2
/5AWG
NOTE: The wire size is only for reference. If there is a long distance between
the PV array and the controller or between the controller and the battery, larger
wires can be used to reduce the voltage drop and improve performance.
WARNING: Risk of electric shock!
Use fuses or breakers in solar and battery circuits is recommended
and make them keep OFF state before connection.
WARNING: Risk of electric shock!
Exercise caution when handling solar wiring. The solar PV array can
produce open circuit voltages in excess of 150 V when in sunlight.
Pay more attention to it.
WARNING: Risk of explosion or fire!
Never short circuit battery positive (+) and negative (-) or cables.
Pay more attention to it
AVERTISSEMENT : Risque d'électrochoc!
L'utilisation de fusibles ou coupe-circuits dans le module solaire, le
chargeur et les circuits de la batterie est recommandée, ils doivent
être tenus en position éteinte avant la connexion.
AVERTISSEMENT : Risque d'électrochoc!
Faites attention lors de la manipulation des connexions solaires. La
matrice PV solaire peut produire des tensions supérieures à 150V, à
la lumière du soleil. Soyez particulièrement attentif à cela.
AVERTISSEMENT : Risque d'explosion ou d'incendie!
Ne court-circuitez jamais les pôles positifs (+) et négatifs (-) de la
batterie ou les câbles. Soyez particulièrement attentif à cela.