Plasma Technics Inc. 1900 William St. Racine, WI 53404-1875 Phone : (262) 637-7180 fax : (262) 637-7157
Web Page http://www.plasmatechnics.com E-Mail: sales@plasmatechnics.com Page 7
Features Continued:
User-adjustable HIGH and LOW load-current bracketing. Either high current or low current produce a fault
which is reported to the terminal strip as well as LEDs, which can then be handled as a soft fault or hard fault.
Soft means a user-provided PLC can decide what action is taken before the inverter is disengauged. A hard fault
will automatically provide an OFF command to disengage the inverter output.
Pulse Width and Frequency control in manual mode provide for complete system flexibility.
Onboard potentiometers to control frequency, power (PDM), and output voltage (Pulse Width) can be jumpered
in or out individually, if off-board control is desired.
Inputs easily interface to PLC or computer. 4-20 ma input or 0-20 ma control of power (PDM) for simple and
linear ORP interface, if desired. Also, jumper configurability for 0-10vdc allows interfacing to all common
closed- loop control devices. Frequency and Voltage (Pulse Width) optionally controlled via 0 – 10vdc.
Additional user-terminal strip interfaces: Output ON (implies no faults); scaled buss volts; scaled buss current; 1x
inverter clock frequency, soft / (latched) hard fault.
Safety lockouts and automatic-fault shutdown should short-circuit or over-temperature conditions occur. Fault
status is latched and is reported via LEDS to aid technicians. Indicators include: Output ON, Instantaneous, and
long-term over current, over temp.
PDM, Voltage and Frequency potentiometers have their own jumper selection for on board control if
desired.
Push-On, Push-Off or toggle-switch control, inputs and simulates contact logic for simple management of
ON/OFF function.
Buss-Voltage Compensation maintains nearly constant output voltage should line voltage drift. Compensation is
automatically scaled for 120v and 240v operation.
Control connections of the essential I/O functions are the same as the SSD110 and Plasma Block®.
Full pulse-by-pulse current limit control for all power output devices for reliable operation.
Short input power loss ride-through stabilizes performance during line-voltage fluctuations.
All control connections are fully isolated from power line reference to enable simple and safe connection to other
equipment.
Normal frequency range of 50hz, adjustable to 30khz with built-in IGBT protection circuits.
Military grade conformal coating eliminates problems associated with condensation and mold as well as
greatly retarding damaged caused by accidental ozone exposure.