Specifications

Plasma Technics Inc. 1900 William St. Racine, WI 53404-1875 Phone : (262) 637-7180 fax : (262) 637-7157
Web Page http://www.plasmatechnics.com E-Mail: sales@plasmatechnics.com Page 5
lock-out in the event of power loss. A user- selectable output compensation circuit maintains a relatively constant
primary voltage as the input line-voltage fluctuates. Customer configurable op. amp. inputs are available at the barrier
strip to enable customers the ability to scale, invert, mix and level shift control signals if necessary.
Installation Drawing
Example SSD110 Outputs:
Full Frequency / Full RMS Voltage Typical PDM Waveform
-1.00
-0.50
0.00
0.50
1.00
0
0
Voltage
Sizing:
Part Device Inverter Output Output PTI
Number Rating/Phase Output/Phase Voltage Power Transformers
(ARMS) (ARMS) (VRMS) (KVA) /Leg
SSD110/15 25.0 15.0 240 / 120 3.6 / 1.8 1-HLHxx302/D230
3-HLHxx102/D115
Input specifications:
AC input 90 to 264 (VRMS) single-phase, 50/60hz. DC input voltage 120 to 373 (VDC).
Forced cooling may be required in addition to the provided fan, and is to be provided by customer.
Consult factory for pricing and availability of unlisted models. Prices are subject to change without notice.