Serial Communications
Asynchronous port: EIA RS-232 and RS-422/485, isolated, 0.3 to 19.2 kbaud
ANSI-x3.28-2.5-A4 protocol standard;
Optional Allen-Bradley DF1, Modicon RTU, and
Johnson Controls N2 protocols
Synchronous port: EIA RS-485 for high-speed master/slave networking
Typical Parameters and Displays:
Programmable Parameters
Set point User I/O parameter selections
Set point minimum S-ramp profile smoothing
Set point maximum Switching frequency
Set point units label, Master / slave select / source
Scaling, precision Slave ratio / position phasing
Set point source Keypad enable
(3) skip frequencies Security code
(3) skip bandwidths
Minimum / maximum
Current limit
Restart retries / delay
Analog I/O scaling / polarity
User analog input mode
Status Displays
Buss voltage Energy consumption
Power factor Accumulated thermal load
Output current Accumulated time run
Output frequency Fault log and conditions
Power consumption Input status
Protection
Ground fault Power transistor fault
Output phase-to-phase short circuit Logic power under-voltage
DC buss over-voltage Remote command signal loss
DC buss under-voltage Memory malfunction
Instantaneous over-current Processor not running fault
Output overload Synchronous serial error
Heat sink over-temperature
Ambient over-temperature
Power Range
Input Constant-Torque Variable-Torque Extended-Torque
Voltage Applications Applications Applications
230 VAC 11/2-15 hp (1.1-11 kW) 2-20 hp (1.5-15 kW)
380 VAC 11/2-25 hp (1.1-18 kW) 2-30 hp (1.5-22 kW)
460 VAC 11/2-25 hp (1.1-18 kW) 2-30 hp (1.5-22 kW) 25-40 hp (18-30 kW)
Consult factory for other powers. Other voltages require appropriate de-rating.
I n v e r t e r s