Specifications

Plasma Technics Inc. 1900 William St. Racine, WI 53404-1875 Phone : (262) 637-7180 fax : (262) 637-7157
Web Page http://www.plasmatechnics.com E-Mail: sales@plasmatechnics.com Page 10
SECTION 2. Suggested soft start circuits
FUSE
FUSE
MOV
FUSE
FUSE
FUSE
MOV
MOV
MOV
50 OHMS 25 W
RELAY SPST
3
4
5
3
4
5
Circuits are shown for both single phase (top) and three phase inputs (bottom). Components to the right of
the inverter are typical ozone generator components.
A general rule is to use the three phase circuit if the generator is rated over 2 KW. However this is a matter
of individual preference.
Section 3 Bill of Materials
INVERTER 70250 ASSEMBLY
PART NO.
DESCRIPTION
SOURCE
NOTES
U2125A330L
Ceramic surge resistor
HVRA
716.693.4700
www.hvrapc.com
W9AS1D52-
5
30 Amp 5 VDC coil relay
Magnecraft
866.433.5722
www.alliedelec.com
DF30AA160
30 Amp three phase rectifier
SanRex
516.625.1313
0.2 uF 1600 VDC/530 VAC capacitor
ASC or PTI
308.284.3611
www.ascapacitor.com
235
14 Amp DC link choke (inductor)
PTI
4 KVA maximum
237
20 Amp DC link choke (inductor)
PTI
> 4 KVA use the 237
DAT210
Inverter to 4 KW
PTI
Purchased separately