User Manual
Pearl-2 User Guide                                     
In that case, you can manually upload an EDID and force Pearl-2 to use a specific set of attributes for a specific 
HDMI input port. All video sources you connect to that HDMI input port will use the EDIDyou've manually 
assigned to the port. 
EDID changes remain in effect for the HDMI input port until you replace the EDID with another 
one or specifically choose to restore the factory EDID for that specific HDMI input port. A system-
level factory reset does not remove a manually assigned EDID from the HDMI port.
1.  To download a new EDID file, go to the Epiphan support web page and select the support page for 
Pearl-2.
2.  Scroll to the EDID section and select an EDIDfrom the list. The file is saved to your downloads folder 
on your hard drive.
3.  Connect to the Admin panel  and log in as admin. See Connect to the Admin panel
4.  From the Inputs menu, select the input port for which you want to upload the EDID. 
5.  On the configuration page for that source, scroll to the EDID upload section and click Choose FIle.
6.  Browse to the location where the custom EDID file was saved and select it, then click open. 
7.  Click upload. When the upload is complete, the page updates to reflect success or failure.
Restore factory default EDID
When you no longer want a custom EDID assigned to an input port, you can restore the input port to use the 
factory default EDID.Currently there is no way to tell if your input port is using a custom EDID. If you are 
457